Permit Number:
08 4282
Permit Type:
Commercial Building Permit - None FillGrade
Address:
W 5000 INTERNATIONAL AIRPORT RD Anchorage
Location:
Work Description:
Work Descr: 13,712 cy fill / 8,059 cy excavation, Remarks: mgm
Status:
Issued
Project Name:
Review Type:
Structural
Result:
Approved
Result Date:
4/24/2008 12:00:00 AM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. C(1): PERMIT STATUS (no response required) 4/8/08: Review completed, comments issued. 4/24/08: APPROVED C(2): GRADING, EXCAVATION AND FILL CODE Advisory Comment (no response required): The Anchorage Administrative Code (AAC) 23.10 and Anchorage Municipal Code (AMC) 23.105 apply to projects involving grading, excavation and fill operations. They can be read and/or downloaded from the Internet at http://www.muni.org/iceimages/BSD/2006admin.pdf and http://www.muni.org/iceimages/BSD/2006grading.PDF. References in the comments are to these codes. C(3): ENGINEERED GRADING - GEOTECHNICAL REPORT Because this project includes grading in excess of 5,000 cubic yards, it is defined as Engineered Grading in accordance with AMC 23.105.106.3. Please provide a geotechnical report in accordance with AMC 23.105.106.3.1. Note: AMC 23.105.105 defines grading as "any excavating or filling or combination thereof". 4/24/08: SATISFIED C(4): FILL - COMPACTION The plans do not appear to include requirements for compaction of fills. Please include on the plans requirements for compaction of fills in accordance with AMC 23.105.110.4 and the project specific soils report required in comment 3 above. 4/24/08: SATISFIED C(5): FILL - LIFT THICKNESS Please show on the plans requirements for the fill lift thickness in accordance with the geotechnical report recommendations. For projects that do not have geotechnical report recommendations, the fill lift thickness shall not be greater than 12 inches. AMC 23.105.106.3.1 4/24/08: SATISFIED C(6): FILL - TYPE Please include on the plans requirements for the type of fill using the Municipality Of Anchorage fill type identification system. AMC 105.106.3.1 Note: Although there may be other ways to do it, a couple of possible methods would be to use a conversion/gradation table or revise all of the affected callouts to be using the MOA identification system. 4/24/08: SATISFIED C(7): SPECIAL INSPECTION Because this project exceeds 5,000-cy of material, it is defined as Engineered Grading in accordance with AMC 23.105.106.3. Accordingly, AMC 23.105.114.1 requires special inspection in accordance with the 2006 International Building Code (IBC). Please include on the plans the requirements for special inspection as set forth in IBC 1704.7. Note: this is a new code requirement as of the first of the year. 4/24/08: SATISFIED C(8): BUILDING SAFETY INSPECTION REQUIREMENTS Because this project exceeds 5,000-cy of material, it is defined as Engineered Grading in accordance with AMC 23.105.106.3. Accordingly, the code requires inspections by the Building Safety inspector. Please include on the plans the requirements for Building Safety inspection as set forth in AMC 23.105.114.2E. 4/24/08: SATISFIED
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
RSS
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501