Permit Number: 06 6160
Permit Type: Commercial Building Permit - None Sign
Address: 3101 PENLAND PKWY Anchorage
Location:
Work Description: Work Descr: 1 illuminated sign, Remarks: gjs
Status: Closed
Project Name: DENALI ALASKAN FCU
Review Type: Structural
Result: Approved
Result Date: 1/23/2007 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. C(1): The anchors specified do not have an approved ICC report stating allowable values installed in the face of concrete masonry. C(2): Where the manufactures published allowable values are compared to the component and cladding loads of table 1609.6.2(2) of the 2003 IBC, the anchors are inadequate to supportthe design loads. Please choose an anchor with a higher capacity, or specify additional anchors.