Permit Number: 04 6272
Permit Type: Commercial Building Permit - None BldgNew
Address: 301 Gull AVE Anchorage
Location:
Work Description: Work Descr: 8640 sqft fabric structure, Remarks: gjs
Status: Closed
Project Name: BLDG #1
Review Type: Fire
Result: Approved
Result Date: 2/24/2005 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. C(1): ADDRESS: Provide a street address for the building. The address shall be plainly visible/legible from the street or road fronting the building. Is the address on Gull Ave? Where is fire truck entry point? C(2): KEY BOX: Must install adjacent to the front main entrance at 6' above grade prior to the CO inspection. Knox box info may be obtained at Fire Prev. 4700 S Bragaw, 267-4900. C(3): WATERFLOW: Provide information on flow available. Show hydrant locations & distances from property and building. AWWU computer projections may be accepted for permitting. 2400 gpm required. C(4): FIRE EXTINGUISHERS: Provide fire extinguishers. C(5): GAS METER protection: Provide bollards: minimum 4" diameter by six feet (3' buried in a 15" diameter concrete footing; 3' above ground) and they must befilled with concrete. Min. 3 feet from meter and max. 4 feet apart. C(6): Membrane and Inner liner material shall be either non-combustible or flame-resistant to NFPA 701. Provide specifications for this material. Received Report 2/3/05 FEC Okay C(7): Fire Access: Where would a fire truck enter to get next to this building.? C(8): Asphalt floor: Is it the intent to seal to make non-absorbant?? NA C(9): EXIT HARDWARE: Open from inside w/one motion, no special knowledge or effort. No thumb turns or separate deadbolts. No keyed locks except front main entrance (if one door or a single pair). C(10): EMERGENCY LIGHTING is required as two exits are required. Emergency lighting shall extend to the exterior adjacent to the exit discharges. C(11): FIRE REVIEW STATUS: DISAPPROVED 12/31/04 Carpenter C(12): Please provide a written response to all comments dated 12/31/04 & update drawings as applicable. Resubmitted architectural drawings do not include details showing address, knoxbox, fire extinguisher, exterior emergency lighting, bollard protection for exterior gas & electric service. Please provide a copy of fire flow & membrane material for my file in the new submittal. C(13): FIRE REVIEW STATUS: DISAPPROVED 2/1/05 FURCH @ 267-4964. C(14): APPROVED 1/11/04 Carpenter Additional emegency lighting required as 2 exits are required for common path per item #10 above.
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS