Permit Number: 04 5164
Permit Type: Commercial Building Permit - None BldgAlter
Address: W 601 5TH AVE Anchorage
Location:
Work Description: Work Descr: Tenant Improvement, Remarks: cm
Status: Expired
Project Name: KEYBANK PLAZA STARBUCKS
Review Type: Fire
Result: Approved
Result Date: 4/27/2004 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. C(1): SPRINKLER SYSTEM: A separate submittal review, & permit is required for all changes and additions to the sprinkler system. Provide a current inspection report showing all deficiencies have been repaired prior to final inspection and an installation certificate for all new work. How will the arctic entry/vestibule be sprinklered? C(2): DOOR ENCROACHMENT: The door at the women's restroom encroachers into the egress path. IBC 1003.2.3.1 C(3): EMERGENCY LIGHTS: Provide at exterior exit discharge per IBC 1003.2.11.2 RESOLVED 4/27/04 furch exterior fixture to be weather proof C(4): OCCUPANT LOAD SIGN: Provide as required per 1003.2.2.5. Round up numbers for retail, storage and accessory space. Two exits required asoccupant load is > 49. Recalculate total number as plans show 43 actual seats plus accessory areas. Provide panic hardware, emergency lighting, exit and other required signage. Resolved 4/27/04 using58 occuppant load furch C(5): FIRE ALARM: A seperate submittal review, & permit is required for additions and changes to the fire alarm system. Provide an install certificate for all new work and a current inspection report for the existing system showing all deficiencies have been corrected prior to the final inspection. C(6): DOOR HARDWARE: Provide details of door hardware. Panic hardware is required per local amendment and IBC 1003.3.1.9 & 1003.3.1.9. RESOLVED 4/27/04 per phone conversation with Amanda - Door 001 to be panic hardware. no "Door Unlock..." sign required. furch C(7): FIRE EXTINGUISHER: Provide as required per IFC 906 for size, type, travel distance. Show location on plan. Inspector will field verifyat final. C(8): MEZZANINE EXIT: Please provide additional details of the mezzanine area. How does the removal of the stairs effect exiting to include occupant load and travel distance? The stairs appears to be a required exit off the mezzanine. Please address. C(9): FIRE REVIEW STATUS: Disapproved 3/30/04 Furch 267-4964 C(10): FIRE REVIEW STATUS: Approved 4/27/04 furch All items resolved. C(11): 4/29/04 submittal on soffet. Fire info only. 7/9/04 furch
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS