Register
My Neighborhood
Jobs
Contact Us
Home
Residents
Businesses
Government
Visitors
Departments
Public Safety
Transportation
Recreation
ePay
Maps
Services A-Z
Muni.org
>
Departments
>
Development Services
> Permit Information & Inspection Request
Click Here To Go Back To Permit Information
Permit Number:
04 5164
Permit Type:
Commercial Building Permit - None BldgAlter
Address:
W 601 5TH AVE Anchorage
Location:
Work Description:
Work Descr: Tenant Improvement, Remarks: cm
Status:
Expired
Project Name:
KEYBANK PLAZA STARBUCKS
Review Type:
Fire
Result:
Approved
Result Date:
4/27/2004 12:00:00 AM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. C(1): SPRINKLER SYSTEM: A separate submittal review, & permit is required for all changes and additions to the sprinkler system. Provide a current inspection report showing all deficiencies have been repaired prior to final inspection and an installation certificate for all new work. How will the arctic entry/vestibule be sprinklered? C(2): DOOR ENCROACHMENT: The door at the women's restroom encroachers into the egress path. IBC 1003.2.3.1 C(3): EMERGENCY LIGHTS: Provide at exterior exit discharge per IBC 1003.2.11.2 RESOLVED 4/27/04 furch exterior fixture to be weather proof C(4): OCCUPANT LOAD SIGN: Provide as required per 1003.2.2.5. Round up numbers for retail, storage and accessory space. Two exits required asoccupant load is > 49. Recalculate total number as plans show 43 actual seats plus accessory areas. Provide panic hardware, emergency lighting, exit and other required signage. Resolved 4/27/04 using58 occuppant load furch C(5): FIRE ALARM: A seperate submittal review, & permit is required for additions and changes to the fire alarm system. Provide an install certificate for all new work and a current inspection report for the existing system showing all deficiencies have been corrected prior to the final inspection. C(6): DOOR HARDWARE: Provide details of door hardware. Panic hardware is required per local amendment and IBC 1003.3.1.9 & 1003.3.1.9. RESOLVED 4/27/04 per phone conversation with Amanda - Door 001 to be panic hardware. no "Door Unlock..." sign required. furch C(7): FIRE EXTINGUISHER: Provide as required per IFC 906 for size, type, travel distance. Show location on plan. Inspector will field verifyat final. C(8): MEZZANINE EXIT: Please provide additional details of the mezzanine area. How does the removal of the stairs effect exiting to include occupant load and travel distance? The stairs appears to be a required exit off the mezzanine. Please address. C(9): FIRE REVIEW STATUS: Disapproved 3/30/04 Furch 267-4964 C(10): FIRE REVIEW STATUS: Approved 4/27/04 furch All items resolved. C(11): 4/29/04 submittal on soffet. Fire info only. 7/9/04 furch
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
RSS
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501