Project Name: KEYBANK PLAZA STARBUCKS
Review Type: Electrical
Result: Approved
Result Date: 4/21/2004 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. C(1): The following comments are based on the 2002 National Electrical Code and should be resolved before a permit is issued. This correction list is not a building permit.The approval of plans and specifications does not permit the violation of any section of the NEC, or any federal, state or local amendments to these codes. RESPONSE 4-21-04. NO RESPONSE IS REQUIRED C(2): Sheet E 1.1 (One Line Diagram - Arc Flash Protection Marking). Article 110-16 requires that switchboards, panel boards, industrial control panels, and motor control centers that are likely to required examination, adjustment, servicing, or maintenance while energized shall be field marked to warn qualified persons of potential electric Arc Flash Hazards. The marking shall be located so as to be clearly visible to qualified persons before examination, adjustment, servicing or maintenance. Please add marking on the plan. RESPONSE 4-21-04. MARKING IS ADDED TO THE PLAN. APPROVED. C(3): Sheet E-1.1 (Panel Schedule AIC). Panel A and Panel B are not provided with the amperage interrupting ampacity as required by 2002 NEC Section 110.9 and the Anchorage Administrative Code AAC 23.10.302.3. Please address. RESPONSE 4-21-04. AIC IS ADDED TO PANELS. APPROVED. C(4): Sheet E 1.1 (Existing Service Load Calculation). The plan is not provided with the feeder load calculation for the existing building asrequired by 2002 NEC Section 220.35(1). Please review and advise. RESPONSE 4-21-04. EXISTING FEEDER CALCULATION IS ADDED TO PLAN. APPROVED. C(5): Sheet E 2.1 (One Line Diagram - Transformer Grounding Conductor). The 150 KVA Transformer is not provided with proper size grounding conductor. Refer to Anchorage Administrative Code AAC 23.10.302.3. Please address. RESPONSE 4-21-04. TRANSFORMER GROUNDING DETAILS IS ADDED TO PLAN. APPROVED. C(6): ELECTRICAL STATUS: APPROVED AS NOTED C(7): ELECTRICAL STATUS: APPROVED AS NOTED
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS