Permit Number: 02 5498
Permit Type: Commercial Building Permit - None BldgAlter
Address: E 800 DIMOND BLVD Anchorage
Location:
Work Description: Work Descr: RACKING FOR BEST BUY STORE, Remarks: CAH
Status: Expired
Project Name: BEST BUY RACKING
Review Type: Structural
Result: Approved
Result Date: 8/14/2002 12:00:00 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

C(1): Storage racks require periodic special inspection of anchorages per IBC 1707.5. Welding requires special inspection. Please indicate who will perform special inspection and provide information on special inspector qualifications for review. Please clarify special inspector responsibilities and clarify who will hire the special inspector. Theowner or engineer-architect of record acting as the owner's agent should employ the special inspector and not the contractor. The special inspector shall observe the work for conformance with the plans and furnish reports to the building department. The permit cannot be issued until the special inspection program is approved. Reference: IBC 1704.1, IBC 1704.1.1, IBC 1704.1.2, 23.10.302.5 7/31/02 Comment: Special inspection is required storage rack anchors specifically per IBC 1707.5. Periodic special inspection is required for welding unless it is performed by an approved fabricator per IBC 1704.2. Please provide verification that the f