Register
My Neighborhood
Jobs
Contact Us
Home
Residents
Businesses
Government
Visitors
Departments
Public Safety
Transportation
Recreation
ePay
Maps
Services A-Z
Muni.org
>
Departments
>
Development Services
> Permit Information & Inspection Request
Click Here To Go Back To Permit Information
Permit Number:
99 5733
Permit Type:
Commercial Building Permit - None BldgNew
Address:
6200 BOEING AVE Anchorage
Location:
Work Description:
Work Descr: 20,715 sq ft warehouse 10-15-99 updated underground plbg permit to include total scope of work cr, Remarks:
Status:
Closed
Project Name:
MAPCO WAREHOUSE, BLDG B
Review Type:
Traffic Engineering
Result:
Correction
Result Date:
Comments:
Code Section
Review Comment
Status
Advisory Information:
. . All 8' h.c. accessible aisles require a 'No Parking sign. Show location on site plan. See attached example. OK 8/16/99 MA. All 8' h.c. accessible aisles require a 'No Parking sign. Show location on site plan. See attached example. OK 8/16/99 MA. Correct h.c. sign installation detail. See attached example. OK 8/16/99 MAH Add dimensions. Add 'No Parking sign location information. Correct h.c. sign installation detail. See attached example. OK 8/16/99 MAH Add dimensions. Add 'No Parking sign location information. Include 8' van accessible aisle striping and signing information on h.c. parking detail. OK 8/16/99 MA. Include 8' van accessible aisle striping and signing information on h.c. parking detail. OK 8/16/99 MA. Include slope information in h.c. ramp detail. Slope not to exceed 1:12. OK 8/16/99 MA. Include slope information in h.c. ramp detail. Slope not to exceed 1:12. OK 8/16/99 MA. Resolve location of 8' h.c. accessible aisle for h.c. parking stall at the NE corner of the NE parking area. Title 21.45.080.W.8 states "The accessible route of travel shall not pass behind parking spaces." OK 8/16/99 MA. Resolve location of 8' h.c. accessible aisle for h.c. parking stall at the NE corner of the NE parking area. Title 21.45.080.W.8 states "The accessible route of travel shall not pass behind parking spaces." OK 8/16/99 MA. Eliminate the 2 parking stalls closest to the building in the SE parking area. Parking spaces cannot be located next to this building and also this will allow maneuvering room for vehicles exiting the 2 stalls closest to the building. OK 8/16/99 MA. Eliminate the 2 parking stalls closest to the building in the SE parking area. Parking spaces cannot be located next to this building and also this will allow maneuvering room for vehicles exiting the 2 stalls closest to the building. OK 8/16/99 MA. Requires Certified Site Lighting Analysis. See attached example. Requires Certified Site Lighting Analysis. See attached example. Requires Certified Glare Statement. See attached example. OK 8/16/99 MA. Requires Certified Glare Statement. See attached example. OK 8/16/99 MA
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
RSS
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501