Permit Number:
99 5713
Permit Type:
Commercial Building Permit - None BldgNew
Address:
6200 BOEING AVE Anchorage
Location:
Work Description:
Work Descr: 32,452 sq ft warehouse, 32,452 sq ft sprinklered, Remarks: 10-15-99 updated plbg permit cr
Status:
Closed
Project Name:
MAPCO WAREHOUSE, BLDG A-2
Review Type:
Traffic Engineering
Result:
Correction
Result Date:
8/12/1999 10:13:07 AM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. . All 8' h.c. accessible aisles require a 'No Parking' sign. Show location on site plan. See attached example. OK 8/12/99 MA. All 8' h.c. accessible aisles require a 'No Parking' sign. Show location on site plan. See attached example. OK 8/12/99 MA. Correct h.c. sign installation detail. See attached example. OK 8/12/99 MAH Add dimensions. Add 'No Parking' sign location information. Correct h.c. sign installation detail. See attached example. OK 8/12/99 MAH Add dimensions. Add 'No Parking' sign location information. Include 8' van accessible aisle stripping and signing information on h.c. parking detail. OK 8/12/99 MA. Include 8' van accessible aisle stripping and signing information on h.c. parking detail. OK 8/12/99 MA. Include slope information in h.c. ramp detail. Slope not to exceed 1:12. OK 8/12/99 MA. Include slope information in h.c. ramp detail. Slope not to exceed 1:12. OK 8/12/99 MA. Resolve location of 8' h.c. accessible aisle for h.c. parking stall at the NE corner of the NE parking area. Title 21.45.080.W.8 states "The accessible route of travel shall not pass behind parking spaces. OK 8/12/99 MA. Resolve location of 8' h.c. accessible aisle for h.c. parking stall at the NE corner of the NE parking area. Title 21.45.080.W.8 states "The accessible route of travel shall not pass behind parking spaces. OK 8/12/99 MA. Eliminate the 2 parking stalls closest to the building in the SE parking area. Parking spaces cannot be located next to this building and also this will allow maneuvering room for vehicles exiting the 2 stalls closest to the building. OK 8/12/99 MA. Eliminate the 2 parking stalls closest to the building in the SE parking area. Parking spaces cannot be located next to this building and also this will allow maneuvering room for vehicles exiting the 2 stalls closest to the building. OK 8/12/99 MA. Requires Certified Site Lighting Analysis. See attached example. Requires Certified Site Lighting Analysis. See attached example. Requires Certified Glare Statement. See attached example. Requires Certified Glare Statement. See attached example