Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: 99 5512
Permit Type: Commercial Building Permit - None BldgAlter
Address: E 800 DIMOND BLVD Anchorage
Location:
Work Description: Work Descr: retail tenant improvement, 9525 sq ft, type 2, sprinklered /td, Remarks: permittype =ALT/RETAIL, status= FINAL 10/25/99, planstatus=
Status: Closed
Project Name: GAP / GAP BODY
Review Type: Fire
Result: Approved
Result Date: 10/23/1999 9:48:05 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. . Is this Type II building one- hour or non-rated?? Is this portion of mall a V-1hr?. Is this Type II building one- hour or non-rated?? Is this portion of mall a V-1hr?. Provide building footprint to show location of different construction types and of location of these occupancies. Only a partial provided which does not give a clear picture. Provide building footprint to show location of different construction types and of location of these occupancies. Only a partial provided which does not give a clear picture. Sheet A2-0: Required exit cannot be through staging( storage) area. Sheet A2-0: Required exit cannot be through staging( storage) area. Add exit signs at rear exit areas to easily identify path of egress. Add exit signs at rear exit areas to easily identify path of egress. Provide merchandise dispay lay-out and identify aisle areas as access to exits. Provide merchandise dispay lay-out and identify aisle areas as access to exits. Uniform Fire Code 1002 FIRE EXTINGUISHERS: Provide fire extinguishers per Uniform Fire Code Standard 10-1. Show on plans. Uniform Fire Code 1002 FIRE EXTINGUISHERS: Provide fire extinguishers per Uniform Fire Code Standard 10-1. Show on plans. Uniform Fire Code 1001.5 FIRE PROTECTION SYSTEMS-REPORTS: Provide a current service report for each fire system in the building. All deficiencies must be corrected prior to calling for a final C.O. Uniform Fire Code 1001.5 FIRE PROTECTION SYSTEMS-REPORTS: Provide a current service report for each fire system in the building. All deficiencies must be corrected prior to calling for a final C.O. Uniform Fire Code 1001.3 FIRE PROTECTION SYSTEMS - Permits: Submit plans and apply for separate review and permits fo. Uniform Fire Code 1001.3 FIRE PROTECTION SYSTEMS - Permits: Submit plans and apply for separate review and permits fo. Provide occupant load calculations. Provide occupant load calculations. Uniform Fire Code 1207.3 EXIT HARDWARE: Open from inside w/one motion, no special knowledge or effort. No thumb turns or separate deadbolts. No keyed locks except front main entrance (if one door or a single pair). Uniform Fire Code 1207.3 EXIT HARDWARE: Open from inside w/one motion, no special knowledge or effort. No thumb turns or separate deadbolts. No keyed locks except front main entrance (if one door or a single pair). Emergency Lighting: Unsure of locations. Emergency Lighting: Unsure of locations. Uniform Mechanical Code 608 AUTOMATIC SHUTOFFS (activated by smoke detection): Required in each system providing over 2000 cfm heating or cooling air. Verif. Uniform Mechanical Code 608 AUTOMATIC SHUTOFFS (activated by smoke detection): Required in each system providing over 2000 cfm heating or cooling air. Verif. Verify roof/ceiling assembly will be protected by damper when penetrated by ductwork. Verify roof/ceiling assembly will be protected by damper when penetrated by ductwork. Do alarmlock doors have a delay?. Do alarmlock doors have a delay?. Flame-spread- provide for wall covering material and verify required flame-spread. Flame-spread- provide for wall covering material and verify required flame-spread. FIRE REVIEW STATUS: DISAPPROVED 6/29/99 Carpente. FIRE REVIEW STATUS: DISAPPROVED 6/29/99 Carpente. Reviewed resubmittal, letter from Gensler. APPROVED 7/22/99 Carpente. Reviewed resubmittal, letter from Gensler. APPROVED 7/22/99 Carpente. Revised plans received/approved 8/28/99. Foste. Revised plans received/approved 8/28/99. Foste
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter