Permit Number:
98 6185
Permit Type:
Commercial Building Permit - None BldgAlter
Address:
W 5000 INTERNATIONAL AIRPORT RD Anchorage
Location:
Work Description:
Work Descr: demo and remodel of existing space for pen-air/era relocation of contract "c"/ checked in by Ross/gjs--Demo for non-sturctural app c. kustin 02-2-99-cah, Remarks: permittype =ALT/BAGGAGE CLAIM, status= FINAL 10/22/99, planstatus=
Status:
Closed
Project Name:
BAGGAGE CLAIM PENN AIR/ERA
Review Type:
Electrical
Result:
Correction
Result Date:
2/4/1999 2:34:44 PM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. . The following comments are based on the 1996 National Electrical Code and the 1994 Uniform Building Code and should be resolved before a permit is issued. This correction list is not a building permit.The approval of plans and specifications does not permit the violation of any section of the NEC, UBC or any federal, state or local amendments to these code. The following comments are based on the 1996 National Electrical Code and the 1994 Uniform Building Code and should be resolved before a permit is issued. This correction list is not a building permit.The approval of plans and specifications does not permit the violation of any section of the NEC, UBC or any federal, state or local amendments to these code. On Sheet E801, the wire size from 800/3 in MDP-1Hto 500 KVA transformer appears to be undersized per 240-3(c). Please verify. On Sheet E801, the wire size from 800/3 in MDP-1Hto 500 KVA transformer appears to be undersized per 240-3(c). Please verify. On Sheet E801, verify overload protection for escalators to verify wire sizes from 90/3 breakers. On Sheet E801, verify overload protection for escalators to verify wire sizes from 90/3 breakers. On Sheet E801, the wire from 30 KVA transformer to Panel EPA indicates 5-#2 + 1-#8. Please verify wire count. On Sheet E801, the wire from 30 KVA transformer to Panel EPA indicates 5-#2 + 1-#8. Please verify wire count. ELECTRICAL STATUS: CORRECTIONS REQUIRE. ELECTRICAL STATUS: CORRECTIONS REQUIRE