Permit Number:
98 5644
Permit Type:
Commercial Building Permit - None BldgNew
Address:
3950 AIRCRAFT DR Anchorage
Location:
Work Description:
Work Descr: 3,000 sq ft metal hanger type -v-1hr per Ron thompson RD, Remarks: permittype =NEW AIRCRAFT HANGER, status= FINAL 11/18/99, planstatus=
Status:
Closed
Project Name:
AIRCRAFT HANGER
Review Type:
Fire
Result:
Correction
Result Date:
3/15/1999 8:22:24 AM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. . Uniform Fire Code 901.4.4 ADDRESS: Provide a street address for the building. The address shall be plainly visible/legible from the street or road fronting the building. Ok will show on bldg. Uniform Fire Code 901.4.4 ADDRESS: Provide a street address for the building. The address shall be plainly visible/legible from the street or road fronting the building. Ok will show on bldg. CODE STUDY: Provide a complete code study for the building to include allowable area calculations, building construction type, yard size(s). Site Plan showing distances to property lines and show occupancy classification. What type of work will be done inside besides the parking of an aircraft? 3000 s.f. 5-N constr. Lease lot from INAP lot lines ok...10 ft from row. CODE STUDY: Provide a complete code study for the building to include allowable area calculations, building construction type, yard size(s). Site Plan showing distances to property lines and show occupancy classification. What type of work will be done inside besides the parking of an aircraft? 3000 s.f. 5-N constr. Lease lot from INAP lot lines ok...10 ft from row. Uniform Building Code 1003.3 EXIT ARRANGEMENT: 2 exits shall be placed a distance apart = than 1/2 the max. overall diagonal of the area served. Show a floor plan of bldg. showing all exits. (Man doors...overhead doors are not acceptable as exits.) O/L of 6...only 1 exit required. Uniform Building Code 1003.3 EXIT ARRANGEMENT: 2 exits shall be placed a distance apart = than 1/2 the max. overall diagonal of the area served. Show a floor plan of bldg. showing all exits. (Man doors...overhead doors are not acceptable as exits.) O/L of 6...only 1 exit required. Uniform Fire Code 1207.3 EXIT HARDWARE: Open from inside w/one motion, no special knowledge or effort. No thumb turns or separate deadbolts. No keyed locks except front main entrance (if one door or a single pair). O. Uniform Fire Code 1207.3 EXIT HARDWARE: Open from inside w/one motion, no special knowledge or effort. No thumb turns or separate deadbolts. No keyed locks except front main entrance (if one door or a single pair). O. Uniform Fire Code 902.2 FIRE ACCESS: Provide a 20' wide lane to within 150' of all portions of the building. Use a minimum clear height of 13'6" and a 40' inside diameter turn radius. Show access on the plans. OK from roa. Uniform Fire Code 902.2 FIRE ACCESS: Provide a 20' wide lane to within 150' of all portions of the building. Use a minimum clear height of 13'6" and a 40' inside diameter turn radius. Show access on the plans. OK from roa. Uniform Fire Code 1002 FIRE EXTINGUISHERS: Provide fire extinguishers per Uniform Fire Code Standard 10-1. Show on plans! will provid. Uniform Fire Code 1002 FIRE EXTINGUISHERS: Provide fire extinguishers per Uniform Fire Code Standard 10-1. Show on plans! will provid. Uniform Fire Code 1001.3 FIRE PROTECTION SYSTEMS - Permits: Submit plans and apply for separate review and permits for f/a or s/s. None require. Uniform Fire Code 1001.3 FIRE PROTECTION SYSTEMS - Permits: Submit plans and apply for separate review and permits for f/a or s/s. None require. FIRE SAFETY DURING CONSTRUCTION: Access and water supply shall be installed (prior to construction other than foundation). UFC 94 sets guidelines for construction safety procedures. Show on plans location of hydrants and provide from AWWU fire flow from existing hydrants. Additional hyrants could be required, depending on code study. 1 hydr. req. and provided. FIRE SAFETY DURING CONSTRUCTION: Access and water supply shall be installed (prior to construction other than foundation). UFC 94 sets guidelines for construction safety procedures. Show on plans location of hydrants and provide from AWWU fire flow from existing hydrants. Additional hyrants could be required, depending on code study. 1 hydr. req. and provided. Uniform Fire Code 902.4 KEY BOX: Must install adjacent to the front main entrance at 6' above grade prior to the CO inspection. Knox box info may be obtained at Fire Prev., 1301 E. 80th (267-4960). Show on plans. Will provided by main enstrance. 9/8/98 approved. furnance will be minimum of 18" above any ignition sources. Uniform Fire Code 902.4 KEY BOX: Must install adjacent to the front main entrance at 6' above grade prior to the CO inspection. Knox box info may be obtained at Fire Prev., 1301 E. 80th (267-4960). Show on plans. Will provided by main enstrance. 9/8/98 approved. furnance will be minimum of 18" above any ignition sources