Permit Number: 98 5086
Permit Type: Commercial Building Permit - None BldgAlter
Address: 700 G ST Anchorage
Location:
Work Description: Work Descr: TENANT IMPROVMENT TO 7TH FLOOR AND COUPLE ROOMS ON 8TH FLOOR, Remarks: permittype =ALT/OFFICE, status= FINAL 7/10/98, planstatus=
Status: Closed
Project Name:
Review Type: Architectural
Result: Approved
Result Date: 3/12/1998 11:27:57 AM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. . The following comments based on the 1994 Uniform Building Code should be resolved before a permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the Uniform Building Code or any federal, state or local regulations. The following comments based on the 1994 Uniform Building Code should be resolved before a permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the Uniform Building Code or any federal, state or local regulations. Dead end corridors should not exceed 20 feet. Section 1005.5. Please verify compliance. IT LOOKS AS THOUGH ROOM 703 IS IN CORRIDOR AND WOULD CREATE A DEAD END. DEPENDS UPON ANSWER TO ITEM #3. APPROVED: N/. Dead end corridors should not exceed 20 feet. Section 1005.5. Please verify compliance. IT LOOKS AS THOUGH ROOM 703 IS IN CORRIDOR AND WOULD CREATE A DEAD END. DEPENDS UPON ANSWER TO ITEM #3. APPROVED: N/. THE ENTIRE FLOOR WITH CONFERENCE ROOMS LOOKS TO HAVE AN OCCUPANT LOAD GREATER THAN 100. I MAY NEED TO BE BROUGHT UP TO SPEED REGARDING WHY A 2 HOUR AREA SEPARATION WALL IS ALLOWED TO BE USED TO SEPARATE THE BUILDINGS WHEN A FOUR HOUR IS REQUIRED. PLEASEGIVE ME A CALL TO DISCUSS 343-8326. IF TWO HOUR IS THE PAST AGREEMENT THEN ALL EXITING IS OK. OTHERWISE ALL CORRIDORS WILL BE REQUIRED TO BE RATED WITH PROTECTED OPENINGS. APPROVED: 3 HOUR DOOR IS IN PLACE AND 4 HOUR WALL ALREADY EXISTS. THE ENTIRE FLOOR WITH CONFERENCE ROOMS LOOKS TO HAVE AN OCCUPANT LOAD GREATER THAN 100. I MAY NEED TO BE BROUGHT UP TO SPEED REGARDING WHY A 2 HOUR AREA SEPARATION WALL IS ALLOWED TO BE USED TO SEPARATE THE BUILDINGS WHEN A FOUR HOUR IS REQUIRED. PLEASEGIVE ME A CALL TO DISCUSS 343-8326. IF TWO HOUR IS THE PAST AGREEMENT THEN ALL EXITING IS OK. OTHERWISE ALL CORRIDORS WILL BE REQUIRED TO BE RATED WITH PROTECTED OPENINGS. APPROVED: 3 HOUR DOOR IS IN PLACE AND 4 HOUR WALL ALREADY EXISTS. ARCHITECTURAL STATUS: APPROVED AS NOTE. ARCHITECTURAL STATUS: APPROVED AS NOTE
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS