My Neighborhood
Contact Us
Muni.org
>
Departments
>
Development Services
> Permit Information & Inspection Request
Click Here To Go Back To Permit Information
Permit Number:
97 5790
Permit Type:
Commercial Building Permit - None BldgNew
Address:
W 325 8TH AVE Anchorage
Location:
Work Description:
Work Descr: 111 unit hotel 61995 sq ft Elevator Stops 3 weight 2500 valuation 29,950 manufacturer dover Serial Number EH 8013, Remarks: permittype =NEW HOTEL, status= FINAL 6/18/98, planstatus=
Status:
Closed
Project Name:
CLARION SUITES
Review Type:
Fire
Result:
Approved
Result Date:
9/28/1998 2:38:37 PM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. . Full review not done-- Footing and foundation approved 14 Aug 97 F. Full review not done-- Footing and foundation approved 14 Aug 97 F. Provide electrical plans to verify exit signs, low-level exit signs and emergency lighting and stand alone smoke detectors (not connected to the fire alarm) in each unit. Detectors shall be in the bedrrom and outside of and dual powered. Provide electrical plans to verify exit signs, low-level exit signs and emergency lighting and stand alone smoke detectors (not connected to the fire alarm) in each unit. Detectors shall be in the bedrrom and outside of and dual powered. fire protection systems - Permits: Submit plans and apply for separate review and permiting for each system. (Sprinkler system, Fire Alarm. fire protection systems - Permits: Submit plans and apply for separate review and permiting for each system. (Sprinkler system, Fire Alarm. Sprinkler FDC shall be at the front or response side of structure. Sprinkler FDC shall be at the front or response side of structure. Provide details of furnace vent- enclosed in a shaft?. Provide details of furnace vent- enclosed in a shaft?. Pool and Meeting Rooms 137 and 139 (Combo ) are assembly occupancies? ( Exits open in path of egress with panic hardware , emergency lighting and lighted exits signs on all exits. Panic hadware shall be on exits available to these rooms to the exteriorof building. Pool and Meeting Rooms 137 and 139 (Combo ) are assembly occupancies? ( Exits open in path of egress with panic hardware , emergency lighting and lighted exits signs on all exits. Panic hadware shall be on exits available to these rooms to the exteriorof building. EXIT HARDWARE: Open from inside w/one motion, no special knowledge or effort. No thumb turns or separate deadbolts except from individual units. Provide key to hardware groups listed. EXIT HARDWARE: Open from inside w/one motion, no special knowledge or effort. No thumb turns or separate deadbolts except from individual units. Provide key to hardware groups listed. Provide mechanical drawing. Provide mechanical drawing. Additional doors at elevators shall be 20 minute smoke assemblies. Additional doors at elevators shall be 20 minute smoke assemblies. Provide details of bath exhaust shaft and penetration of. Provide details of bath exhaust shaft and penetration of. Provide details of listed Fire-stopping assemblies for all sizes of pipe and type. Provide details of listed Fire-stopping assemblies for all sizes of pipe and type. Draftstop in attic -- greatest horizontal distance shall be 100 feet. Plans reflect 119 feet??. Draftstop in attic -- greatest horizontal distance shall be 100 feet. Plans reflect 119 feet??. UBC 310.4- Verify escape window size to this section. These windows not indicated on window schedule. UBC 310.4- Verify escape window size to this section. These windows not indicated on window schedule. UBC 804- Verify Flame Spread rating for vinyl wall covering and fiberglass wainscot. UBC 804- Verify Flame Spread rating for vinyl wall covering and fiberglass wainscot. Provide detail of party wall at bathtub to verify continuity of separation. Provide detail of party wall at bathtub to verify continuity of separation. FIRE EXTINGUISHERS: Provide 2A10BC fire extinguishers sealed and tagged with a current service date. FIRE EXTINGUISHERS: Provide 2A10BC fire extinguishers sealed and tagged with a current service date. Sheet G1.2- Floor/ truss/ ceiling system- provide Gypsum association , ICBO or UL listing. Sheet G1.2- Floor/ truss/ ceiling system- provide Gypsum association , ICBO or UL listing. Attic access- verify 1 hr fire assembly. Attic access- verify 1 hr fire assembly. Verify canopy and supporting columns are of 1 hr constru. Verify canopy and supporting columns are of 1 hr constru. Resubmittal 9/15/97 Electrical and Mechanica. Resubmittal 9/15/97 Electrical and Mechanica. Rooms that have door on bedroom shall be provided with a dual powered smoke detector outside the bedroom intertied to the one in the bedroom. When one is activated the other is also. Rooms that have door on bedroom shall be provided with a dual powered smoke detector outside the bedroom intertied to the one in the bedroom. When one is activated the other is also. Pool and Rooms 137 and 139- provide exit signs at required exits. Exterior exits meet only 1/2 the required exiting. Pool and Rooms 137 and 139- provide exit signs at required exits. Exterior exits meet only 1/2 the required exiting. Provide approved low level exit signs- not shown on electrical plans. Provide approved low level exit signs- not shown on electrical plans. Fire Dept. Connection shall be at front or response side of building. Fire Dept. Connection shall be at front or response side of building. Provide written response to all comments and show on plans. Provide written response to all comments and show on plans
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501