Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: 97 5790
Permit Type: Commercial Building Permit - None BldgNew
Address: W 325 8TH AVE Anchorage
Location:
Work Description: Work Descr: 111 unit hotel 61995 sq ft Elevator Stops 3 weight 2500 valuation 29,950 manufacturer dover Serial Number EH 8013, Remarks: permittype =NEW HOTEL, status= FINAL 6/18/98, planstatus=
Status: Closed
Project Name: CLARION SUITES
Review Type: Electrical
Result: Approved
Result Date: 9/28/1998 2:38:29 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

. . The following comments are based on the 1996 National Electrical Code and the 1994 Uniform Building Code and should be resolved before a permit is issued. This correction list is not a building permit.The approval of plans and specifications does not permit the violation of any section of the NEC, UBC or any federal, state or local amendments to these code. The following comments are based on the 1996 National Electrical Code and the 1994 Uniform Building Code and should be resolved before a permit is issued. This correction list is not a building permit.The approval of plans and specifications does not permit the violation of any section of the NEC, UBC or any federal, state or local amendments to these code. E2.1 - A separate branch circuit shall supply the car lights, receptacle(s), auxiliary lighting power source, and ventilation on each elevator car per NEC 620-22. Please provide compliance with this section. COMMENT ADDRESSE. E2.1 - A separate branch circuit shall supply the car lights, receptacle(s), auxiliary lighting power source, and ventilation on each elevator car per NEC 620-22. Please provide compliance with this section. COMMENT ADDRESSE. E2.1 - A separate branch circuit shall supply the machine room/machinery space lighting and receptacle(s). Required lighting shall not be connected to the load side terminals of a ground-fault circuit-interrupter receptacle(s) per NEC 620-23 (a). Please provide compliance. COMMENT ADDRESSE. E2.1 - A separate branch circuit shall supply the machine room/machinery space lighting and receptacle(s). Required lighting shall not be connected to the load side terminals of a ground-fault circuit-interrupter receptacle(s) per NEC 620-23 (a). Please provide compliance. COMMENT ADDRESSE. E2.1 - Please locate a receptacle within 5' and no greater than 10' from spa as required by 680-41 (a). COMMENT ADDRESSED. E2.1 - Please locate a receptacle within 5' and no greater than 10' from spa as required by 680-41 (a). COMMENT ADDRESSED. E5.1 One-Line Diagram - Please provide concrete encased electrode as required by 250-81(c). COMMENT ADDRESSE. E5.1 One-Line Diagram - Please provide concrete encased electrode as required by 250-81(c). COMMENT ADDRESSE. E5.1One-line Diagram and Note 15 - Please verify that GFI protection is provided for the service entrance equipment as required by 230-95. COMMENT ADDRESSED. E5.1One-line Diagram and Note 15 - Please verify that GFI protection is provided for the service entrance equipment as required by 230-95. COMMENT ADDRESSED. New drawings submitted have deleted the horn/strobes out of the guest rooms. This is in violation of the American with Disabilites section 4.28.4 as adopted by Municipality Title 23.70. Please revise drawings to indicate horn/stobes. New drawings submitted have deleted the horn/strobes out of the guest rooms. This is in violation of the American with Disabilites section 4.28.4 as adopted by Municipality Title 23.70. Please revise drawings to indicate horn/stobes. ELECTRICAL STATUS: CORRECTIONS REQUIRE. ELECTRICAL STATUS: CORRECTIONS REQUIRE
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS