Permit Number:
97 5790
Permit Type:
Commercial Building Permit - None BldgNew
Address:
W 325 8TH AVE Anchorage
Location:
Work Description:
Work Descr: 111 unit hotel 61995 sq ft Elevator Stops 3 weight 2500 valuation 29,950 manufacturer dover Serial Number EH 8013, Remarks: permittype =NEW HOTEL, status= FINAL 6/18/98, planstatus=
Status:
Closed
Project Name:
CLARION SUITES
Review Type:
Architectural
Result:
Approved
Result Date:
11/3/1998 10:46:48 AM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. . The following comments based on the 1994 Uniform Building Code are in response to the Architects response to the original review comments. These comments must be resolved before a permit is issued. The approval of plans and specifications does not permit the violation of any section of the Uniform Building Code or any federal, state or local regulations. The following comments based on the 1994 Uniform Building Code are in response to the Architects response to the original review comments. These comments must be resolved before a permit is issued. The approval of plans and specifications does not permit the violation of any section of the Uniform Building Code or any federal, state or local regulations. Since Choice Picks 125 is over 750 square feet and has an occupant load over 50, it is classified as an A3 occupancy and a one hour occupancy separation is required in accordance with Table 3-B to separate it from Lobby 128.ADDRESSED 10-31-97. Since Choice Picks 125 is over 750 square feet and has an occupant load over 50, it is classified as an A3 occupancy and a one hour occupancy separation is required in accordance with Table 3-B to separate it from Lobby 128.ADDRESSED 10-31-97. Laundry room 141, Door 133: A one hour rated door is required per section 711.4. Revise plans to indicate compliance. ADDRESSED 10-31-97. Laundry room 141, Door 133: A one hour rated door is required per section 711.4. Revise plans to indicate compliance. ADDRESSED 10-31-97. Drawing 1/A3.0: Local Amendment 23.15.1505.3 requires that at least 50 percent of the required ventilation area be provided by ventilators located in the upper portion on the space ventilated at least 3 feet above the eave vents. Revise plans to show compliance. ADDRESSED 10-31-97. Drawing 1/A3.0: Local Amendment 23.15.1505.3 requires that at least 50 percent of the required ventilation area be provided by ventilators located in the upper portion on the space ventilated at least 3 feet above the eave vents. Revise plans to show compliance. ADDRESSED 10-31-97. Roof drainage should not flow over public property. Section 1506. The drawings should show the discharge locations of the roof gutter downspouts to verify compliance. Also, heat trace is required to prevent the gutter system from freezing, thus allowing the roof to drain onto public property along the north side of the building. ADDRESSED 10-31-97. Roof drainage should not flow over public property. Section 1506. The drawings should show the discharge locations of the roof gutter downspouts to verify compliance. Also, heat trace is required to prevent the gutter system from freezing, thus allowing the roof to drain onto public property along the north side of the building. ADDRESSED 10-31-97. Door Schedule: Door 101 serving stairway 100 should be 3'-6" wide per section 1003.2 and 2/G1.1. The door schedule on sheet A7.0 still indicates a 3'-0" door. ADDRESSED 10-31-97. Door Schedule: Door 101 serving stairway 100 should be 3'-6" wide per section 1003.2 and 2/G1.1. The door schedule on sheet A7.0 still indicates a 3'-0" door. ADDRESSED 10-31-97. Provide ICBO Evaluation Report for EIFS application when available. NOT YET PROVIDED, 10-31-97. Provide ICBO Evaluation Report for EIFS application when available. NOT YET PROVIDED, 10-31-97
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501