Permit Number:
97 5481
Permit Type:
Commercial Building Permit - None BldgAlter
Address:
2751 DEBARR RD Anchorage
Location:
Work Description:
Work Descr: TENANT IMPROVEMENT FOR DR.MASON NO VALUATION PER MASTER FILE 96-5215, Remarks: permittype =ALTERATION OFFICE, status= COMPLETE 9/9/97, planstatus=
Status:
Closed
Project Name:
Review Type:
Electrical
Result:
Approved
Result Date:
6/16/1997 2:30:06 PM
Comments:
Code Section
Review Comment
Status
Advisory Information:
. . The reviewer cannot determine what is part of this contract and what is not. In the future please delineate areas by contract/permit. If a comment is made that does not apply to this permit, just reply with NIC, No response required. The reviewer cannot determine what is part of this contract and what is not. In the future please delineate areas by contract/permit. If a comment is made that does not apply to this permit, just reply with NIC, No response required. Electrical Single Line Diagram - Is this all new equipment? IF a new service is being added to the building please provide which exception to NEC 230-2 the designer is using along with verificatio. Electrical Single Line Diagram - Is this all new equipment? IF a new service is being added to the building please provide which exception to NEC 230-2 the designer is using along with verificatio. Please show equipment grounding conductor from 225A breaker to panel 3. Please show equipment grounding conductor from 225A breaker to panel 3. Note on E1.3 indicates that panel 3LC is identical to 3LB. This must mean as far as panel size, type and voltage, because the branch circuitry is different. Please provide complete panel schedule and load analysis. Note on E1.3 indicates that panel 3LC is identical to 3LB. This must mean as far as panel size, type and voltage, because the branch circuitry is different. Please provide complete panel schedule and load analysis. Panel 3H - 75 KVA transformer feeding 3LA,B and C does not appear to have the correct load. Please revise for proper load. Panel 3H - 75 KVA transformer feeding 3LA,B and C does not appear to have the correct load. Please revise for proper load. No branch circuit or switching is shown for lights in room S301 (from Arch).. No branch circuit or switching is shown for lights in room S301 (from Arch).. Please provide egress lighting in all corridors, per UBC 101. Please provide egress lighting in all corridors, per UBC 101