| Date | Status | Code | Description | Ref | Location | Comments |
| 10/22/2025 | Corrected | PlumbRgh14 | Comments | See Inspectors Comments | Water Pipe | Leaking 3/4" ProPress 90 at tie in location |
| 10/22/2025 | Corrected | PlumbRgh14 | Comments | See Inspectors Comments | Ice Maker | 2018 UPC 609.10 Water Hammer. Building water supply systems where quick-acting valves are installed shall be provided with water hammer arrestors.
2018 UPC MOA Amendment 609.10 Mechanical Devices. Examples of quick-acting valve locations include, but are not limited to, dishwashers, clothes washers, toilet ballcock, icemakers, and any single handle faucet.
|
| 10/22/2025 | Corrected | PlumbRgh14 | Comments | See Inspectors Comments | Water Piping | 2018 UPC 312.9 Steel Nail Plates. Plastic and copper or copper alloy piping penetrating framing members to within 1" of exposed framing shall be protected by steel nail plates not less than 18 gauge in thickness. |