Click Here To View Another Inspection Inspection #: 875621 Inspection Type: Plumbing Inspection Inspector: N.Smith Result: Partial Comment: WORK TO CONTINUE UNDER R20-3008 PERMIT THAT WAS OPENED IN 2020 -PERMIT REQUIRED PER PERMINTTING MANAGER R.DIENES-OEHM- PERMITS WILL NOT BE CLOSED UNTIL SAID CORRECTIONS LISTED BELOW ARE ADDRESSED. Trailer tie downs approved. Temp gas tag issued. GAS = furnace, WH, range. NOTE: Previous permit from when trailer was moved noted that water heater was not installed. Water heater is now installed and was never inspected. There are several corrections listed below. -Flue piping to be secured with at least 3 sheet metal screws -Water heater is free standing - needs to be braced to resist earthquake movement. -Pex shall not be within the first 18" of the water heater -No pan under the water heater -Water heaters relieve valve needs to be pipe to within 6"-24" of the ground with ridged pipe. Inspection Corrections DateStatusCodeDescriptionRefLocationComments