Inspection #: 868856
Inspection Type: Mechanical Inspection
Inspector: N.Jackson
Result: Correction
Comment: MP UG Natural Gas and LP Natural Gas Tests Approved. No Green Tag issued. See Correction

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
8/21/2025TransferMechCommentsSee commentsSee comments belowFAF Vent and Combustion AirConcentric vent and combustion air pipe to be used with FAF. Single wall vent connector not listed/labeled for use with appliance.
8/19/2025CorrectedMechCommentsSee commentsSee comments belowUG Natural Gas Tubing (meter to home reg)2018 UPC Section 1213.3 MP gas systems are to be tested with 60psi air pressure. 