Inspection #: 858605
Inspection Type: Underground Plumbing
Inspector: J.Bean
Result: Correction
Comment: See Correction, all else ok for rough and test. Ok to cover. Note: Will see correction thru access panel at later date

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/24/2025CorrectedUnGrndPlumb11Corrections as FollowsMake corrections as followsDWV System4"x3" Fernco not approved. 2018 UPC 705.2.2 Mechanical Joints and Compression Joints: Mechanical Joints for cast-iron pipe and fittings shall be of the elastomeric compression type or mechanical joint coupling. Compression type joints with an elastomeric gasket are for cast-iron hub and spigot. Mechanical joint shielded coupling type for hub-less cast-iron shall have a metallic shield that complies with ASTM A 1056, ASTM C1277, ASTM C1540 OR CISPI C564