Inspection #: 857343
Inspection Type: Final Mechanical
Inspector: N.Smith
Result: Correction
Comment: See corrections

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/23/2025TransferMechFinalSee commentsSee Inspector CommentsWH flueWH flue connected with only tape. Connect with 3 screws minimum per 2018 IFGC
6/23/2025TransferMechFinalSee commentsSee Inspector CommentsBath fan terminationFan termination missing 1/4" screen per 2018 IMC
6/23/2025TransferMechFinalSee commentsSee Inspector CommentsBathroom fanBathroom fan not operational
6/23/2025TransferMechFinalSee commentsSee Inspector CommentsRange hoodRange hood not operational.