Inspection #: 857314
Inspection Type: Plumbing Inspection
Inspector: N.Jackson
Result: Approved
Comment: Corrections Addressed. UG Med Press Nat Gas piping Approved. Green Tag Issued. Nat Gas service to include 1-Dryer, 1-FAF, 1-WH, 1-Range.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/5/2025TransferPlmbCommentSee Commentssee commentsUG Natural Gas Test Gauge (Meter End) Medium pressure natural gas to be tested for 30 min at 60psi for piping carrying gas pressures in excess of 14 IWC, per 2018 UPC Section 1213.3
6/5/2025TransferPlmbCommentSee Commentssee commentsUG Natural Gas Tracer WireUtilize an approved (for direct burial) conductor of not less than 18AWG is to be utilized for UG tracer wire, per 2018 IFGC Section 404.17.3.