Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 853195
Inspection Type: Final Electrical
Inspector: N.Holland
Result: Correction
Comment: See Corrections

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/3/2025TransferCorrect Below* PanelBlank off open spaces Panel schedule required.
5/6/2025CorrectedCorrect Below* FurnaceRomex shall not be exposed in feeding the furnace. Box for shutoff switch needs an cover.
5/6/2025TransferCorrect Below* BondingNeed access under the trailer to verify gas, water, and steel framing is all bonded. UPDATE: Bonding of water, gas, and framing Ground wire shall land in panel. Service conductors shall be protected and not exposed.
5/6/2025CorrectedCorrect Below* Panel1) Was unable to take off panel cover. 2) All 120V circuits shall be AFCI and GFCI protected. 3) Update panel schedule 4) Dryer circuit shall be GFCI protected
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS