Inspection #: 853183
Inspection Type: Final Plumbing
Inspector: N.Jackson
Result: Correction
Comment: See Corrections

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/4/2025TransferPlumbFinalCommentsSee Inspector CommentsShower/Tub Valve (bathroom)Shower/tub thermostatic mixing valve not tested for temperature.
5/6/2025CorrectedPlumbFinalCommentsSee Inspector CommentsNatural Gas UG Meter to RegUG Natural Gas tubing damaged at regulator connection. Repair and test with 60psi, per 2018 UPC Section 1213.3.
5/6/2025CorrectedPlumbFinalCommentsSee Inspector CommentsBathroom WC and TubJoints between fixture and wall or floor to be made water-tight (caulked) per 2018 UPC Section 402.2
5/6/2025CorrectedPlumbFinalCommentsSee Inspector CommentsKitchen Sink TailpieceSink tailpiece corrugated PVC. Not listed approved for installation. Replace with approved slip coupling extension.
5/6/2025CorrectedPlumbFinalCommentsSee Inspector CommentsBathroom Lav DrainLavatory drains through illegal unvented S-trap. Prohibited per 2018 UPC Section 1004.1 Install vent to serve fixture.
5/6/2025CorrectedPlumbFinalCommentsSee Inspector CommentsDishwasher Air Gap Install dishwasher air gap fitting in accordance with 2018 UPC Section 414.3
5/6/2025CorrectedPlumbFinalCommentsSee Inspector CommentsWH Drainage PanInstall drainage pan in accordance with 2018 UPC Section 507.5
5/6/2025TransferPlumbFinalCommentsSee Inspector CommentsWH T&P Discharge Piping No discharge piping installed. Install approved material pipe to discharge into approved location for appliance Per 2018 UPC Section 608.5