Inspection #: 851598
Inspection Type: Final Electrical
Inspector: N.Holland
Result: Correction
Comment: Electrical work was done without an inspection before covering. Will require AFCI/GFCI circuit protection for all 120V circuits. More corrections may be discovered at next inspection with proper access. See Corrections

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
5/6/2025TransferCorrect Below* FurnaceRomex shall not be exposed in feeding the furnace. Box for shutoff switch needs an cover.
5/6/2025TransferCorrect Below* BondingNeed access under the trailer to verify gas, water, and steel framing is all bonded.
5/6/2025TransferCorrect Below* Panel1) Was unable to take off panel cover. 2) All 120V circuits shall be AFCI and GFCI protected. 3) Update panel schedule 4) Dryer circuit shall be GFCI protected