Inspection #: 835471
Inspection Type: Plumbing Inspection
Inspector: K.Hanson
Result: Correction
Comment: Gas test approved, gas appliances to include 2-WHs & 2-FAFs. See corrections. NOTE: WH (H & CW) piping, DWV & water tie-ins incomplete.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
12/11/2024TransferWaterHtrR20See commentssee commentsBoth WHsSupport required to maintain proper stability of WHs (Fir out/back up WH w/ 2x4s & tighten straps).
12/11/2024TransferPlmbCommentSee Commentssee commentsBoth FAFsCombustion air shall be ducted to the outside, beyond location of future skirting related to mobile home.
12/11/2024TransferWaterHtrRpl13Combustion Air RequiredCombustion air is required - UPC 507.1 and IFGC local amendment 304.8.1.4 to 304.8.1.4.1.2Both WHs 
12/11/2024TransferWaterHtrR20See commentssee commentsEasternmost WHvent not properly centered on/connected to WH.