Inspection #: 835125
Inspection Type: Plumbing Rough
Inspector: E.Huckaba
Result: Partial
Comment: Plumbing rough in, test and inspection- APPROVED. NOTES: PLUMBING ROUGH IN FOR ROOMS # 265 THROUGH 299 AND 299b MINUS ROOM 280. OK TO COVER.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/20/2024TransferBackflowInspTested and TaggedBackflow assembly shall be tested and properly tagged- UPC 603.4.2Irrigation BP 
6/20/2024TransferPlumbRgh9PlansApproved plans must be on site  
6/20/2024TransferGasPipeComSee comments Boiler gas pipingUnion fitting required downstream of boiler isolation valves to serve each boiler per 2018 IFGC.
6/20/2024TransferGasRgh14PipingSee commentssee commentsBoiler gas pipingUnion fitting required downstream of boiler isolation valves to serve each boiler per 2018 IFGC.