Inspection Type: Foundation
Inspector: thomas.green
Result: Partial
Comment: Inspection for rebar in footing at Grid Lines P8 @ MC-ML. Footing rebar conditionally approved pending engineer approval of stepped footings as installed. Provide letter from engineer stating his approval. Contractor to proceed at own risk until engineer makes determination. Special inspector report in attachments.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
12/12/2024TransferFOUNTSee Inspe ctor commentsInspector commentsFooting steps on ends of wall. Confer with design professional as to required spacing horizontally between vertical steps in footing on ends of footing.