Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 832702
Inspection Type: Plumbing Inspection
Inspector: N.Jackson
Result: Approved
Comment: Corrections Addressed

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
11/14/2024CorrectedWaterHtrRpl2Relief Valve TerminationRelief valve discharge shall be 6" to 24" above finish floor or final grade - UPC local amendment 608.0 and UPC 608.5RELIEF VALVE PIPINGCURENTLY RELIEF VALVE PIPING IS RAN IN COPPER WITH A SECTION RAN IN PEX. PEX IS NOT LISTED FOR RELIEF VALVE PIPING.
11/14/2024CorrectedWaterHtrRpl13Combustion Air RequiredCombustion air is required - UPC 507.1 and IFGC local amendment 304.8.1.4 to 304.8.1.4.1.2 AIR INTAKE PIPING NOT RAN. NO COMBUSTION AIR INTAKE INTO WATER HEATER COMPARTMENT.
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS