Inspection #: 827916
Inspection Type: Plumbing Rough
Inspector: Y.Dovba
Result: Partial
Comment: Dwv and water piping rough-in and tests Approved. (new addition) to include underground 2'' dwv piping serving coffee area, along with 3/4'' underground piping was relocated and not able to be tested due to leaking curb key valve out in the street. (cover at your own risk) 3/4'' brazed 90. Dwv and water piping including all in-wall and ceiling piping (new addition area) to include 2-sets of roof drains a leader piping. NOTE: Dwv vents through roof must meet the cross-sectional area. NOTE: Hammer arresters installed. NOTE: More plumbing to be completed at a later date, which include kitchen fixtures, grease interceptors, grease producing fixtures.