Inspection #: 826166
Inspection Type: Plumbing Rough
Inspector: E.Huckaba
Result: Partial
Comment: H2O piping for ice makers floors 1-4(Room #'s-215, 315 and 415), and H2O rough in in rooms # 235, 237 and 239 test and inspection- APPROVED PER PLANS. NOTES: OK TO COVER.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
9/9/2024TransferPlumbRgh14CommentsSee Inspectors CommentsWater pipingAs per 2018 UPC 609.10 hammer arrestors required.
7/18/2024TransferPlumbRgh14CommentsSee Inspectors Comments Cleanouts required for WC and most sinks. All drain lines on 1st floor beyond 5 feet from main require a cleanout. THIS IS FOR ENTIRE FIRST FLOOR