Inspection #: 820839
Inspection Type: Plumbing Rough
Inspector: K.Hanson
Result: Partial
Comment: Partial Plumbing Rough - Approved Water/gas rough & tests approved, DWV rough only serving units 32-38, OK to cover. Gas serving 1-GUH each unit. NOTE 1: Gas piping incomplete, stubbed into unit 30. NOTE 2: "The piping of the plumbing, drainage and venting systems shall be tested..." per 2018 UPC 712.1, tests will be required to serve the entire DWV system for all further inspections. NOTE 3: Water hammer arrestors required, may inspect at Final if exposed.