Inspection #: 813937
Inspection Type: Final Plumbing
Inspector: K.Hanson
Result: Correction
Comment: Partial Plumbing Final - Approved All else OK regarding lounge remodel, See correction.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
1/28/2025TransferPlumbFinal17Backflow Preventer RequiredAn approved backflow preventer is required-UPC 602.2Steam ovenAs per 2018 UPC 2018 602.1 & Backflow Prevention Manual a hot or cold plumbing system shall not be subject to pressure exceeding the operating pressure. ASSE 1012 backflow preventer rated for steam temps & pressure (vented dual check, Watts 9D or equivalent) required.