Inspection #: 807614
Inspection Type: Plumbing Rough
Inspector: N.Jackson
Result: Correction
Comment: All Above Ground Natural Gas Piping Rough and Test Pass. Vent serving gas fired appliances not connected. To include (1)Water Heater, (1)Range/Oven, (1)FAF. See Corrections

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
9/24/2024CorrectedPlumbRgh14CommentsSee Inspectors CommentsMobile home tie down Install mobile home tie downs in accordance with local amendments and manufacturer's installation instructions.
9/24/2024TransferPlumbRgh14CommentsSee Inspectors CommentsSanitary Drain End of Line Clean OutInstall DWV (Sanitary Drain) End of Line Clean Out accessible outside of skirting.
9/24/2024CorrectedPlumbRgh14CommentsSee Inspectors CommentsBuilding Sanitary Drain to Sewer ConnectionUse proper listed and approved shielded coupling for tie-in point. (ABS/PL to Cast Iron Mission Band)
9/24/2024CorrectedPlumbRgh14CommentsSee Inspectors CommentsForced Air Furnace Vent Maintain FAF vent manufacturer's installation instructions recommended clearance to combustibles.
9/24/2024CorrectedPlumbRgh14CommentsSee Inspectors CommentsUnderground natural gas piping 2018 UPC Local Amendment Section 1210.1.10 Frost heave protection for copper tubing. "At points where copper tube type systems enter or leave the ground, they shall be protected from frost heave action by the incorporation of a suitable above ground 6 inch radius loop, or listed fuel gas piping connector or equal size."
9/24/2024CorrectedPlumbRgh14CommentsSee Inspectors CommentsUnderground Natural Gas PipingTest underground Natural Gas piping at 60psi
9/24/2024CorrectedPlumbRgh14CommentsSee Inspectors CommentsWater Heater Gas FlexReplace existing damaged gas flex, for listed and approved gas flex.
9/24/2024CorrectedPlumbRgh14CommentsSee Inspectors CommentsWater Heater VentWater Heater vent not attached to appliance. Maintain single wall vent manufacturer's recommended 6" clearance to combustibles.