Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 799731
Inspection Type: Shearwall / Exterior
Inspector: P.Calhoun
Result: Cancel
Comment: Requesting an inspection to obtain an Approval to Cover (with air barrier) the exterior shear walls (includes holdowns, strapping, and sheathing nail) from grid lines T-Y/10 at all elevations (ground to roof parapet). Requested by: Sloane Tuttle 9079177244 st@akncs.com

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
4/11/2024TransferEXTSNSee Inspector commentsInspector comments Shear wall panels shall be connected to boundary members per shear wall schedule. Straps shall be connected to boundary members. Fasten shear wall panels to bottom plates per shear wall schedule.
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS