Inspection #: 790955
Inspection Type: Plumbing Rough
Inspector: E.Wood
Result: Correction
Comment: Gas piping and test for the remainder of the gas piping, Approved. OK to cover.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
1/25/2024TransferPlumbRgh14CommentsSee Inspectors CommentsAll the building water piping.Per 608.2 of the 2018 UPC "Where static water pressure in the water supply piping is exceeding 80 PSI an approved-type pressure regulator preceded by an adequate strainer shall be installed and the static pressure reduced to 80 PSI or less. Pressure regulators equal to or exceeding 1 1/2" shall not require a strainer."