Inspection #: 780484
Inspection Type: Final Electrical
Inspector: N.Holland
Result: Approved
Comment: Final Approved

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
10/6/2023CorrectedCorrect Below* Through outSeveral receptacles have an open ground on receptacle. If there is no grounding conductor at these locations all these receptacle shall be AFCI , GFCI protected.
10/6/2023CorrectedCorrect Below* Laundry bathroom areaAll receptacles in this area shall be GFCI protected and washer circuit the gfci function shall be an breaker and not receptacle.
10/6/2023CorrectedCorrect Below* ExteriorReceptacle near front door shall be GFCI protected and have an extra duty rated in use cover.
10/6/2023CorrectedCorrect Below*  Receptacles have an open ground and GFCI receptacle does not function. All receptacles in the kitchen shall be GFCI protected. If replaced will need to be tamper resistant and AFCI protected as well.