Inspection #: 777802
Inspection Type: Final Electrical
Inspector: N.Holland
Result: Correction
Comment: See Corrections

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
10/6/2023TransferCorrect Below* Through outSeveral receptacles have an open ground on receptacle. If there is no grounding conductor at these locations all these receptacle shall be AFCI , GFCI protected.
10/6/2023TransferCorrect Below* Laundry bathroom areaAll receptacles in this area shall be GFCI protected and washer circuit the gfci function shall be an breaker and not receptacle.
10/6/2023TransferCorrect Below* ExteriorReceptacle near front door shall be GFCI protected and have an extra duty rated in use cover.
10/6/2023TransferCorrect Below*  Receptacles have an open ground and GFCI receptacle does not function. All receptacles in the kitchen shall be GFCI protected. If replaced will need to be tamper resistant and AFCI protected as well.
9/19/2023CorrectedCorrect Below* ExteriorRemove all cabling hanging out exterior walls.
9/19/2023CorrectedCorrect Below* Ground wireBond steel framing, and gas piping.