Inspection #: 748421
Inspection Type: Plumbing Rough
Inspector: E.Wood
Result: Partial
Comment: Rough-in to include some new shower valves, retro of tub wastes to showers, and re-stub out of waters to the toilets and lavs, Approved for rooms 100,101,102,103,200,201,202,203,204,300,301,302,303,304,305,306,308. OK to cover. NOTE: See corrections.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
2/10/2023TransferPlumbRgh14CommentsSee Inspectors CommentsTub to shower rooms.Per the 2018 UPC 408.7.5, "Shower receptors shall be tested for water tightness by filling with water to the level of the rough threshold."