Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 747833
Inspection Type: Ceiling Rough Electrical
Inspector:
Result:
Comment:

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
1/6/2023 EC1Correct Below MirrorsEnsure lighted mirrors have approved third party listing and label. Plan notes show leaving 6' of mc cable to connect to mirrors. Wiring method to mirrors will need to be inspected at later date. MC cable required to be installed and supported per article 330.
1/6/2023 EC1Correct Below Access panel planned to be installed at corridor to access junction box and others as necessary.  
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS