Inspection #: 744361
Inspection Type: Ceiling Rough Electrical
Inspector: E.Widman
Result: Partial
Comment: Electrical rough approved for Bathrooms 1 and 2, and corridor. Access panel planned to be installed at corridor to access junction box and others as necessary.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
1/6/2023TransferEC1Correct Below MirrorsEnsure lighted mirrors have approved third party listing and label. Plan notes show leaving 6' of mc cable to connect to mirrors. Wiring method to mirrors will need to be inspected at later date. MC cable required to be installed and supported per article 330.
1/6/2023TransferEC1Correct Below Access panel planned to be installed at corridor to access junction box and others as necessary.  