Inspection #: 722517
Inspection Type: Electrical Service
Inspector: E.Widman
Result: Correction
Comment: See corrections. Underground to trailer approved to cover.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
7/21/2022TransferCorrect service item below* ServicePermanent label at service disconnect required. Ensure label is suitable for the environment and per 2015 Utility ESR-Engraved plastic, or 3m brand stickers with raised letters and UV rated.
7/21/2022TransferCorrect service item below* ParkingSeparate branch circuit, WR type receptacle with extra duty while inuse cover required to be located at parking space. Receptacle on exterior is away from parking and there does not appear to be a separate circuit for this purpose.
7/12/2022CorrectedCorrect service item below* Smoke detectors.Required in each bedroom and CO / smoke detector required in common area.
7/12/2022CorrectedCorrect service item below* 240V dryer receptacle.No circuit in panel.
7/12/2022CorrectedCorrect service item below* Master bedroom ceiling fan.Verify fan rated box.
7/12/2022CorrectedCorrect service item below* Replaced receptacles throughout.Require AFCI protection per NEC 406.4(D).
7/12/2022CorrectedCorrect service item below* GFCI protection per 2017 NEC.Laundry, dishwasher, gas range receptacles do not appear to be GFCI. If protecting with a GFCI breaker (not changing receptacle), AFCI protection not required.
7/12/2022CorrectedCorrect service item below* Conduit chase into panel.Duct seal.
7/12/2022CorrectedCorrect service item below* Underground feeder.Direct burial conductors required to be at least 2ft deep.
7/12/2022CorrectedCorrect service item below* Under mobile home.Direct burial feeder conductors, emerging from grade, require at least, coreflow for physical protection.