Inspection #: 682309
Inspection Type: Electrical Rough
Inspector: N.Holland
Result: Correction
Comment: See Corrections AFCI and GFCI protection where required all replacement receptacles will need to be Tamper Resistant

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
9/13/2021Transfer01See inspection comments ThroughoutNail plates required where romex is within 1 1/4" of face of the stud
9/13/2021Transfer01See inspection comments Through outSecuring and supporting romex. within 12" of boxes and enclosures, and supporting in intervals not exceeding 4 1/2 feet. 2017 NEC 334.30