| Date | Status | Code | Description | Ref | Location | Comments |
| 11/12/2020 | Transfer | PlumbRgh14 | Comments | See Inspectors Comments | EXTERIOR HOLD DOWNS | PER MOA HANDOUT- HOLD DOWNS TO BE INSTALLED PER LISTING. |
| 11/12/2020 | Corrected | PlumbRgh14 | Comments | See Inspectors Comments | ENTRYWAYS | PER MOA HANDOUT- LANDING AND RAILING SHALL BE INSTALLED AND SECURED TO TRAILER. |
| 11/12/2020 | Corrected | PlumbRgh14 | Comments | See Inspectors Comments | SKIRTING | PER MOA HANDOUT ON MANUFACTURED HOMES- A 3" CLEAN OUT MUST BE ACCESSABLE THROUGH THE EXTERIOR OF THE SKIRTING. |
| 11/12/2020 | Corrected | GasPipeRgh | Medium Pressure Test | Medium pressure gas piping requires a 60# test- UPC local amendment 23.25.1210.5.2 | UNDERGROUND GAS PIPING FROM METER TO TRAILER. | |
| 11/12/2020 | Corrected | GasPipeRgh4 | Gas Test Failed | Gas test failed - UPC local amendment 1214.3.2 | HOUSE PIPING | |