Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 623220
Inspection Type: Final Electrical
Inspector: E.Widman
Result: Partial
Comment: Electrical final conditionally approved for move in only until 8/14/20. Corrections required.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
8/7/2020TransferCorrect Below* Securely fasten metal flex at termination of water heater. Ground bushing required. See 250.118 for wiring methods approved for use as equipment grounding conductor/ground fault return path.  
8/7/2020TransferCorrect Below*  Additional information/clarification required at panel schedules. Clearly identify loads served, and em lighting circuit. Add source of supply to panels.
8/7/2020TransferCorrect Below* PlansSubmit changes to MOA plan review.
8/7/2020TransferCorrect Below* Various locations. Receptacles required to be held rigidly at finish. See 406.5 for receptacle mounting. Ensure receptacle is not set back from face plate.
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter