Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 573739
Inspection Type: Framing
Inspector: H.Kahlstrom
Result: Correction
Comment: NOTE: Field conditions do not match construction documents. Contractor is to provide an alternate methods and means submitted and approved by MOA plan review or conform to construction and attachment of kiosk framing details. 1) Provide special inspection report for steel bolting and welding as well as post installed anchors. 2) Provide special inspection for core drilled through penetrations at 2 hr. rated concrete deck and conformance to approved UL listed fire stop system.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
10/4/2019TransferFRAMASee Inspector commentsSee Inspector commentsKiosk constructionProvide special inspections as noted in construction documents.
10/4/2019TransferFRAMHNail Bottom platesNail bottom plates per scheduleframing attachment at kioskprovide approved attachment