Inspection #: 573032
Inspection Type: Electrical Rough
Inspector:
Result:
Comment:

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
7/17/2019 01See inspection comments Under trailer grounding connections to trailer frame from panel, to water line, to gas line. Cannot use self-drilling / self-tapping screws. Use through-bolt and nut. Use foot lug as terminal for wire. Scrape off rust under foot lug.
7/17/2019 01See inspection comments Washer receptacle in bathroom.Needs to be GFCI / AFCI, tamper resistant type.
7/17/2019 01See inspection comments Water heater compartment accessible from exterior only.Receptacle needs to be GFCI, tamper resistant type.
7/17/2019 01See inspection comments Trench from electrical service to under trailer.At trailer end, make sure conductors will be 24 inches deep minimum.