Inspection #: 569514
Inspection Type: Final Electrical
Inspector: D.Rooney
Result: Approved
Comment: Electrical final approved

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/21/2019CorrectedCorrect Below* in unit 9bathroom circuit tripped/shorted
6/21/2019CorrectedCorrect Below* in unit 8complete switches in bathroom
6/21/2019CorrectedCorrect Below* in unit 5bath fan not switched
6/21/2019CorrectedCorrect Below* in mechanical roomcomplete 120V terminations at FA panel
6/21/2019CorrectedCorrect Below* all unitsPaddle fans must be complete or remove and blank off switch
6/21/2019CorrectedCorrect Below* all unitsbathroom receptacle not permitted on circuit with bath fan/heater rated more than 50% of circuit rating