Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 569380
Inspection Type: Final Electrical
Inspector: D.Rooney
Result: Correction
Comment: Corrections required

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/21/2019TransferCorrect Below* in unit 9bathroom circuit tripped/shorted
6/21/2019TransferCorrect Below* in unit 8complete switches in bathroom
6/21/2019TransferCorrect Below* in unit 5bath fan not switched
6/21/2019TransferCorrect Below* in mechanical roomcomplete 120V terminations at FA panel
6/21/2019TransferCorrect Below* all unitsPaddle fans must be complete or remove and blank off switch
6/21/2019TransferCorrect Below* all unitsbathroom receptacle not permitted on circuit with bath fan/heater rated more than 50% of circuit rating
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS