Inspection #: 550192
Inspection Type: Plumbing Rough
Inspector: K.Hanson
Result: Partial
Comment: Partial Plumbing Rough - Approved DWV rough & tests approved serving 1st fl water riser rm, 101-103, 105, 107, 201-203, 205, 207, 301-303, 305, 307, 401-403, 405 & 407, OK to cover. NOTE: Depending on roof/ceiling construction related to interstitial space, protection from freezing to serve water piping may be required.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
1/8/2019CorrectedPlumbRgh14CommentsSee Inspectors Comments3 rooms in grid area 15-24 UNLESS STRUCTURALLY PROHIBITED VENT TIE-IN SHALL BE 6" OR MORE ABOVE FLOOD RIM PER 2012 UPC 905.3
1/8/2019CorrectedPlumbRgh6Nail PlatesNail plate(s) required-UPC 312.9through out grid lines 15-24 all floors on DWV 